![Festo CMMP-AS-***-M0 Series Скачать руководство пользователя страница 86](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119086.webp)
5
Setting parameters
86
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
Examples of calculating the speed factor
Speed
Feed
Gear
Formula
Result
shortened
R/min,
0 DP
R
/
min
1
R
OUT
+
1
R
OUT
1
1
min
+
4096
1
4096 min
1/1
1
1
*
4096
1
4096 min
1
1
min
1
+
4096
1
4096 min
1
1
min
num:4096
div:1
R/min,
2 DP
1/100
R
/
min
(
R
/
100 min
)
1
R
OUT
+
100
R
100
1
1
min
+
4096
1
4096 min
2/3
2
3
*
4096
1
4096 min
1
1
min
100
1
100
1
+
8192
1
4096 min
300
1
100 min
num:2048
div:75
°/s,
1 DP
1/10 °/
s
(
°
/
10 s
)
1
R
OUT
+
3600
°
10
1
1
s
+
60
1
min
+
60 * 4096
1
4096 min
1/1
1
1
*
60*4096
1
4096 min
1
1
s
3600 °
10
1
+
245760
1
4096 min
3600
°
10s
num:1024
div:15
mm/s,
1 DP
1/10
mm
/
s
(
mm
/
10 s
)
63.15
mm
R
å
1
R
OUT
+
631.5
mm
10
1
1
s
+
60
1
min
+
60 * 4096
1
4096 min
4/5
4
5
*
60*4096
1
4096 min
1
1
s
631.5
mm
10
1
+
1966080
1
4096 min
6315
mm
10s
num:131072
div:421
1)
Desired unit at the drive-out
2)
Positioning units per revolution at the drive-out (R
OUT
). Feed constant of the drive * 10
-DP
(points after the decimal)
3)
Time factor_v: desired time unit per internal time unit
4)
Gear factor: R
IN
per R
OUT
5)
Insert values into equation.
Tab. 5.7
Examples of calculating the speed factor
6097
h
: acceleration_factor
The object acceleration_factor converts all acceleration values of the application from
acceleration_units into the internal unit Revolutions per minute per 256 seconds. It consists of
numerator and denominator.
Index
6097
h
Name
acceleration_factor
Object Code
ARRAY
No. of Elements
2
Data Type
UINT32