3.5
EMERGENCY Message
The motor controller monitors the function of its major assemblies. These include the power supply,
output stage, angle transmitter evaluation and the slots Ext1 … Ext3. In addition, the motor (temperat
ure, angle encoder) and limit switch are checked. Incorrect parameter setting can also result in error
messages (division by zero, etc.).
When an error occurs, the error number is shown in the motor controller's display. If several error mes
sages occur simultaneously, the message with the highest priority (lowest number) is always shown in
the display.
3.5.1
Overview
When an error occurs or an error acknowledgment is carried out, the controller transmits an
EMERGENCY message. The identifier of this message is made up of the identifier 80
h
and the node
number of the relevant controller.
2
Error free
Error occured
0
1
3
4
After a reset, the controller is in the status Error free (which it might leave again immediately, because
an error is on hand from the beginning). The following status transitions are possible:
No.
Cause
Significance
0
Initialisation completed
1
Error occurs
No error is present and an error occurs. An EMERGENCY
telegram with the error code of the occurring error is sent.
2
Error acknowledgment
An error acknowledgment (
chap. 6.1.5) is attempted, but not
all causes are eliminated.
3
Error occurs
An error is present and an additional error occurs. An
EMERGENCY telegram with the error code of the new error is
sent.
4
Error acknowledgment
An error acknowledgment is attempted, and all causes are
eliminated. An EMERGENCY telegram with the error code 0000
is sent.
Tab. 3.8
Possible status transitions