Obtaining Status and Statistical Information
Page 29-45
Physical Layer Information
The statistics shown in this section are taken at the physical, or serial, interface level.
Administrative/Operational Status
This field shows the Administrative and Operational Status of this
WSX
port. The status
indicator before the slash refers to the Administrative Status. If
UP
, then the port has been
enabled and can transmit data as long as its Operational Status is also UP. If the Adminis-
trative Status is
DN
, then the port will not pass data even if its physical connection is
good.
The status indicator after the slash refers to the Operational Status. If UP, then the port is
capable of passing data as long as it has been logically enabled at the Administrative
level. If
DN
, then the port cannot pass data because of a problem in the physical connec-
tion (e.g., cable disconnected, WSX could not detect cable type) or because the port is
Administratively Down.
Speed BPS
The configured speed of the port. For a physical
DTE
port, the actual rate is determined
by the
DCE
device to which the
WSX
is attached (i.e., a modem or
DSU
). For a physical
DCE
port, the actual rate is the rate configured through the
frmodify
command.
Intf Type
The type of cable that is plugged into the
WSX
port. The cable may be
DCE
or
DTE
and
one of 5 different serial types. See
Intf Type
on page 29-39 for further information.
Receive CRC Errors
The total number of frames with an invalid frame check sequence received on the port
since the last time the switch was initialized.
Receive Aborts
The total number of frames received that were terminated with an
HDLC
abort sequence
since the last time the switch was initialized. An abort sequence consists of 7 contiguous
bits of ones (1111111).
Receive Overruns
The total number of frames that were not received on the port because the system could
not keep up with the data flow. Receive overrun errors include buffer errors and errors
reported by the
RISC
processor.
Transmit Overruns
The total number of frames that were not transmitted on the port because the system
could not keep up with the data flow. Transmit overrun errors include buffer errors and
errors reported by the
RISC
processor.
Signal Errors
The total number of frames that failed to be received or transmitted due to a loss of
modem signals since the last time the switch was initialized. If the
WSX
port is a physical
DTE
, then this count is the number of frames dropped due to a loss of the Data Set Ready
(
DSR
) signal. If the
WSX
port is a physical
DCE
, then this count is the number of frames
dropped due to a loss of the Data Terminal Ready (
DTR
) signal.
Содержание Omni Switch/Router
Страница 1: ...Part No 060166 10 Rev C March 2005 Omni Switch Router User Manual Release 4 5 www alcatel com ...
Страница 4: ...page iv ...
Страница 110: ...WAN Modules Page 3 40 ...
Страница 156: ...UI Table Filtering Using Search and Filter Commands Page 4 46 ...
Страница 164: ...Using ZMODEM Page 5 8 ...
Страница 186: ...Displaying and Setting the Swap State Page 6 22 ...
Страница 202: ...Creating a New File System Page 7 16 ...
Страница 270: ...Displaying Secure Access Entries in the MPM Log Page 10 14 ...
Страница 430: ...OmniChannel Page 15 16 ...
Страница 496: ...Configuring Source Route to Transparent Bridging Page 17 48 ...
Страница 542: ...Dissimilar LAN Switching Capabilities Page 18 46 ...
Страница 646: ...Application Example DHCP Policies Page 20 30 ...
Страница 660: ...GMAP Page 21 14 ...
Страница 710: ...Viewing the Virtual Interface of Multicast VLANs Page 23 16 ...
Страница 722: ...Application Example 5 Page 24 12 ...
Страница 788: ...Viewing UDP Relay Statistics Page 26 24 ...
Страница 872: ...The WAN Port Software Menu Page 28 46 ...
Страница 960: ...Deleting a PPP Entity Page 30 22 ...
Страница 978: ...Displaying Link Status Page 31 18 ...
Страница 988: ...Displaying ISDN Configuration Entry Status Page 32 10 ...
Страница 1024: ...Backup Services Commands Page 34 14 ...
Страница 1062: ...Diagnostic Test Cable Schematics Page 36 24 ...
Страница 1072: ...Configuring a Switch with an MPX Page A 10 ...
Страница 1086: ...Page B 14 ...
Страница 1100: ...Page I 14 Index ...