The WAN Port Software Menu
Page 28-35
ISDN-BRI Port Example
The following example displays the configuration view screen for an ISDN-BRI port (port 2).
To view 3/2, enter:
wpview 3/2
or
wpv 3/2
A screen similar to following displays:
Configuration View for Slot 3, Port 2.
1)
Admin Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UP
2)
Speed in BPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2048000
3)
Clocking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Split
4)
Protocol Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Frame Relay
8) TOS for Voice Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . a0
9) TOS for Voice Signaling Data . . . . . . . . . . . . . . . . . . . . . . . . 60
10) TOS Mask for both TOS Value. . . . . . . . . . . . . . . . . . . . . . . . e0
11) Signaling IP Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.0.0.0
12) Signaling IP Mask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255.255.255.255
13) KeepAlive Up Count . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0
14) KeepAlive Down Count . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0
15) KeepAlive Timeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
16) DTR Pulse Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0
17) DTR Pulse Count . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0
♦
Note
♦
The ISDN
wpview
menu displays PPP specific line
options described in the section
Modifying a Port
on
page 28-14. However, they do not apply to an ISDN
port, and are not described below.
Admin Status
The options for the Admin Status are
UP
and
DN
. If
UP
, the port has been enabled and
can transmit data as long as its Operational Status is also
UP
. If set to
DN
, the port will not
pass data even if its physical connection is good.
Speed in BPS
This field displays the access rate for the Frame Relay line to the service provider. This
parameter is the speed of the entire connection, not an individual virtual circuit. For
example, if you have a 56 kbps line to your service provider, this field should be set to
56000. A full T1 line would have an access rate of 1,544,000 bps, and a full E1 line would
have an access rate of 2,048,000 bps. For either T1 or E1, you can also have a fractional
service with an access rate that is a multiple of 64 kbps.
Clocking
This field displays either
External
,
Internal
, or
Split
. For a more detailed discussion of
clocking, see
Clocking
under
Modifying a Port
on page 28-14.
Protocol Type
The protocol type can be set to either Frame Relay or Point to Point Protocol (PPP). The
default setting is Frame Relay.
Содержание Omni Switch/Router
Страница 1: ...Part No 060166 10 Rev C March 2005 Omni Switch Router User Manual Release 4 5 www alcatel com ...
Страница 4: ...page iv ...
Страница 110: ...WAN Modules Page 3 40 ...
Страница 156: ...UI Table Filtering Using Search and Filter Commands Page 4 46 ...
Страница 164: ...Using ZMODEM Page 5 8 ...
Страница 186: ...Displaying and Setting the Swap State Page 6 22 ...
Страница 202: ...Creating a New File System Page 7 16 ...
Страница 270: ...Displaying Secure Access Entries in the MPM Log Page 10 14 ...
Страница 430: ...OmniChannel Page 15 16 ...
Страница 496: ...Configuring Source Route to Transparent Bridging Page 17 48 ...
Страница 542: ...Dissimilar LAN Switching Capabilities Page 18 46 ...
Страница 646: ...Application Example DHCP Policies Page 20 30 ...
Страница 660: ...GMAP Page 21 14 ...
Страница 710: ...Viewing the Virtual Interface of Multicast VLANs Page 23 16 ...
Страница 722: ...Application Example 5 Page 24 12 ...
Страница 788: ...Viewing UDP Relay Statistics Page 26 24 ...
Страница 872: ...The WAN Port Software Menu Page 28 46 ...
Страница 960: ...Deleting a PPP Entity Page 30 22 ...
Страница 978: ...Displaying Link Status Page 31 18 ...
Страница 988: ...Displaying ISDN Configuration Entry Status Page 32 10 ...
Страница 1024: ...Backup Services Commands Page 34 14 ...
Страница 1062: ...Diagnostic Test Cable Schematics Page 36 24 ...
Страница 1072: ...Configuring a Switch with an MPX Page A 10 ...
Страница 1086: ...Page B 14 ...
Страница 1100: ...Page I 14 Index ...