Running Frame Fabric Tests on Omni Switch/Routers
Page 36-18
Running Frame Fabric Tests on Omni Switch/Routers
You can test the Omni Switch/Router
Multi VBUS
(
MVBUS
) backplane and the frame fabric
ASIC
of every switching module with the
framefab
command. The syntax for this command is
as follows:
framefab [<repeat_count> | ilb <repeat_count>]
The
<repeat_count>
option lets you set the number of times to run the test, which can be from
0 to 999. If you enter
0
, the
framefab
test will continue indefinitely. If you do not use the
<repeat_count>
option, then the
framefab
test will be executed once.
Using the
<repeat_count>
option requires the use of external cables or wrap plugs for the first
physical port of every switching module in the chassis. The external cables or wrap plugs
used in this test are identical to the one listed in the full duplex port test. See
Omni
Switch/Router Port Test Wrap Cable/Plug Requirements
on page 36-10 for more information.
The
ilb
option, which can be used with the
<repeat_count>
option, performs an internal loop-
back. Using this option performs the
framefab
test without the use of external cables or wrap
plugs.
The chassis should be fully loaded (i.e., Omni Switch/Router modules in all slots) to achieve a
thorough testing of both the frame fabric
ASICs
and the Omni Switch/Router backplane. In
addition, an
MPX
should be installed in Slot 1.
To execute the framefab test indefinitely, for example, enter
framefab 0
at the system prompt. A screen similar to the following will be displayed.
Testing All Slots
Test In Progress: FABRIC Test
Test Summation:
Started: TUE OCT 27 18:40:31 2000
All Slots Passes Fails
FABRIC 1199 18
Failure Summation:
Test Fail No.
Test No.
Exp. Data
Meas. Data
Iter. No.
Time
Temp (C)
FABRIC
1
110402
00004cec
00000000
6
18:50:34
43.0
FABRIC
2
110504
0000a9e4
00000000
13
18:56:45
43.0
FABRIC
3
110307
0008a6ff
00000000
159
21:26:05
43.0
First 3 Failure(s) Detail:
Fail No. 1 - FRAME FABRIC TEST: Slot 5 failed. No packet Received from slot: 3
Fail No. 2 - FRAME FABRIC TEST: Slot 6 failed. No packet Received from slot: 5
Fail No. 3 - FRAME FABRIC TEST: Slot 4 failed. No packet Received from slot: 8
— Output continues on next page —
Содержание Omni Switch/Router
Страница 1: ...Part No 060166 10 Rev C March 2005 Omni Switch Router User Manual Release 4 5 www alcatel com ...
Страница 4: ...page iv ...
Страница 110: ...WAN Modules Page 3 40 ...
Страница 156: ...UI Table Filtering Using Search and Filter Commands Page 4 46 ...
Страница 164: ...Using ZMODEM Page 5 8 ...
Страница 186: ...Displaying and Setting the Swap State Page 6 22 ...
Страница 202: ...Creating a New File System Page 7 16 ...
Страница 270: ...Displaying Secure Access Entries in the MPM Log Page 10 14 ...
Страница 430: ...OmniChannel Page 15 16 ...
Страница 496: ...Configuring Source Route to Transparent Bridging Page 17 48 ...
Страница 542: ...Dissimilar LAN Switching Capabilities Page 18 46 ...
Страница 646: ...Application Example DHCP Policies Page 20 30 ...
Страница 660: ...GMAP Page 21 14 ...
Страница 710: ...Viewing the Virtual Interface of Multicast VLANs Page 23 16 ...
Страница 722: ...Application Example 5 Page 24 12 ...
Страница 788: ...Viewing UDP Relay Statistics Page 26 24 ...
Страница 872: ...The WAN Port Software Menu Page 28 46 ...
Страница 960: ...Deleting a PPP Entity Page 30 22 ...
Страница 978: ...Displaying Link Status Page 31 18 ...
Страница 988: ...Displaying ISDN Configuration Entry Status Page 32 10 ...
Страница 1024: ...Backup Services Commands Page 34 14 ...
Страница 1062: ...Diagnostic Test Cable Schematics Page 36 24 ...
Страница 1072: ...Configuring a Switch with an MPX Page A 10 ...
Страница 1086: ...Page B 14 ...
Страница 1100: ...Page I 14 Index ...