Viewing T1/E1 Local Statistics
Page 33-17
Viewing T1/E1 Local Statistics
There are a number of commands available for viewing local
T1
and
E1
statistics. These
commands provide statistics for the past 24 hours, the current 15-minute interval, or the past
96 15-minute intervals. The following sections describe these commands.
Viewing Total Local Statistics
You can view statistics occurring during the past 24 hours on a single port by entering the
following command
telts <slot>/<port>
where
<slot>
is the slot number where the board is located, and
<port>
is the port number on
the board for which you want to view statistics. For example, to view 24-hour statistics for
Port 2 on the board in slot 5, enter
telts 5/2
A screen similar to the following displays:
Local 24-hour Period Statistics for port 2 on slot 5
Circuit Identifier
: Alcatel T1 Circuit
Valid Intervals
: 1 of 96
Elapsed Time
: 421 of 900
ES
SES
BES
UAS
SEFS
LES
CSS
PCV
LCV
====== ====== ====== ====== ====== ====== ====== ====== ======
3
1
1
0
1
313
0
2
313
Circuit Identifier.
The textual description of this
T1
or
E1
port as configured through the
temod
command.
Valid Intervals
. Indicates the number of 15-minute intervals for which valid statistics were gath-
ered during the previous 24 hours. Statistics may be gathered for up to 96 15-minute intervals
during a 24 hour period.
Elapsed Time
. The number of seconds that have elapsed during this 15-minute interval of gath-
ering statistics. This time will be reset to zero when a 15-minute session of statistics gathering
is complete (and stored) and the next 15-minute interval begins.
ES
. Errored Seconds. For T1-
ESF
and
E1-CRC
conditions, this is a second with one or more
Path Code Violations, one or more out-of-frame defects, one or more controlled slip errors, or
an
AIS
error.
SES
. Severely Errored Seconds. For T1-
ESF
frames, this is a second with 320 or more Path
Code Violation errors, one or more out-of-frame defects, or an
AIS
error. For
E1-CRC
condi-
tions, this is a second with 832 or more Path Code Violation errors, or one or more out-of-
frame defects. For
E1
-no
CRC
signals, this is a second with 2048 or more Line Code Violation
errors. For
D4/(SF)
frames, this is a second with framing errors, an out-of-frame error, or a
second with
1544
or more line code violation errors.
BES
. Bursty Errored Seconds. The number of seconds with fewer than 320 but more than one
(1) Path Code Violation error (see below for definition), no Severely Errored Frame errors,
and no
AIS
errors.
UAS
. Unavailable Seconds. The number of seconds this port was unavailable for transmitting
or receiving data. In general, a port is unavailable after 10 consecutive Severely Errored
Seconds or after a failure on the interface occurs.
Содержание Omni Switch/Router
Страница 1: ...Part No 060166 10 Rev C March 2005 Omni Switch Router User Manual Release 4 5 www alcatel com ...
Страница 4: ...page iv ...
Страница 110: ...WAN Modules Page 3 40 ...
Страница 156: ...UI Table Filtering Using Search and Filter Commands Page 4 46 ...
Страница 164: ...Using ZMODEM Page 5 8 ...
Страница 186: ...Displaying and Setting the Swap State Page 6 22 ...
Страница 202: ...Creating a New File System Page 7 16 ...
Страница 270: ...Displaying Secure Access Entries in the MPM Log Page 10 14 ...
Страница 430: ...OmniChannel Page 15 16 ...
Страница 496: ...Configuring Source Route to Transparent Bridging Page 17 48 ...
Страница 542: ...Dissimilar LAN Switching Capabilities Page 18 46 ...
Страница 646: ...Application Example DHCP Policies Page 20 30 ...
Страница 660: ...GMAP Page 21 14 ...
Страница 710: ...Viewing the Virtual Interface of Multicast VLANs Page 23 16 ...
Страница 722: ...Application Example 5 Page 24 12 ...
Страница 788: ...Viewing UDP Relay Statistics Page 26 24 ...
Страница 872: ...The WAN Port Software Menu Page 28 46 ...
Страница 960: ...Deleting a PPP Entity Page 30 22 ...
Страница 978: ...Displaying Link Status Page 31 18 ...
Страница 988: ...Displaying ISDN Configuration Entry Status Page 32 10 ...
Страница 1024: ...Backup Services Commands Page 34 14 ...
Страница 1062: ...Diagnostic Test Cable Schematics Page 36 24 ...
Страница 1072: ...Configuring a Switch with an MPX Page A 10 ...
Страница 1086: ...Page B 14 ...
Страница 1100: ...Page I 14 Index ...