BGP Commands
show ipv6 bgp path
OmniSwitch CLI Reference Guide
March 2011
page 19-197
-> show ipv6 bgp path ipv6-addr 2020:100:200:1::/64
BGP Path parameters
Path address = 2020:100:200:1::
Path Length = 64
Path protocol = ibgp
Path neighbor = peer(2001:100:3:4::1)
Path nextHop = 2001:100:3:4::1,
Path origin = igp,
Path local preference = 100,
Path state = active,
Path weight = 0,
Path preference degree = 100,
Path autonomous systems = [nAs=0] : <none>,
Path MED = <none>,
Path atomic = no,
Path AS aggregator = <none>,
Path IPaddr aggregator = <none>,
Path community = <none>,
Path Originator Id = <none>,
Path Cluster List = <none>,
Path unknown attribute = <none>
Nbr Address
The IP or IPv6 address of the BGP peer that advertises this path.
(0)
The origin attribute of this route path. A question mark (
?
) indicates
incomplete, and
i
indicates IGP, and an
e
indicates EGP.
degPref
The local preference value assigned to this route path.
output definitions
Path address
The IPv6 address for route path.
Path Length
The prefix length of the IPv6 path.
Path protocol
The protocol from which this route path was learned. Possible values
for this field are as follows:
local
,
static
,
directhost
,
rip
,
ospf
,
isis
,
ibgp
,
ebgp
, and
other
.
Path neighbor
The IPv6 address of the BGP peer.
Path nextHop
The next hop along the route path.
Path origin
The BGP origin attribute. Possible values will be
igp
,
egp
,
incomplete
,
and
none
. The origin attribute is considered during the route decision
process.
Path local preference
The local preference value for this route as received in an UPDATE
message. A negative value (for example, the
-1
in the above display)
indicates that the local preference value is missing for this route path.
Path state
Indicates the state of the path.The possible states are
best
,
feasible
,
pol-
icy-wait
,
un-synchronized
,
dampened
, or
none
. When path state is
none
, it indicates that there are no paths to this prefix and the route is
being purged from the system.
Path weight
The path weight as assigned through inbound and outbound policies.
output definitions (continued)
Содержание 060321-10, Rev. B
Страница 1: ...Part No 060321 10 Rev B March 2011 OmniSwitch CLI Reference Guide www alcatel lucent com...
Страница 36: ...Technical Support About This Guide page xxxvi OmniSwitch CLI Reference Guide March 2011...
Страница 108: ...show udld status port UDLD Commands page 2 22 OmniSwitch CLI Reference Guide March 2011...
Страница 142: ...show vlan members VLAN Management Commands page 4 16 OmniSwitch CLI Reference Guide March 2011...
Страница 324: ...show linkagg range Link Aggregation Commands page 6 66 OmniSwitch CLI Reference Guide March 2011...
Страница 418: ...show lldp remote system med 802 1AB Commands page 9 40 OmniSwitch CLI Reference Guide March 2011...
Страница 922: ...show ip ospf restart OSPF Commands page 17 88 OmniSwitch CLI Reference Guide March 2011...
Страница 968: ...show ipv6 ospf interface OSPFv3 Commands page 18 46 OmniSwitch CLI Reference Guide March 2011...
Страница 1258: ...show ip slb probes Server Load Balancing Commands page 20 50 OmniSwitch CLI Reference Guide March 2011...
Страница 1414: ...show ip dvmrp tunnel DVMRP Commands page 22 34 OmniSwitch CLI Reference Guide March 2011...
Страница 1535: ...PIM Commands show ipv6 pim groute OmniSwitch CLI Reference Guide March 2011 page 23 121 alaPimStarGIAssertWinnerMetric...
Страница 1540: ...show ipv6 pim sgroute PIM Commands page 23 126 OmniSwitch CLI Reference Guide March 2011...
Страница 1814: ...show policy validity period QoS Policy Commands page 26 174 OmniSwitch CLI Reference Guide March 2011...
Страница 1830: ...show policy server events Policy Server Commands page 27 16 OmniSwitch CLI Reference Guide March 2011...
Страница 1853: ...AAA Commands password OmniSwitch CLI Reference Guide March 2011 page 28 23 aaauPassword aaauOldPassword...
Страница 1877: ...AAA Commands show aaa accounting OmniSwitch CLI Reference Guide March 2011 page 28 47 aaacsName4...
Страница 1888: ...show aaa priv hexa AAA Commands page 28 58 OmniSwitch CLI Reference Guide March 2011...
Страница 1902: ...show port mapping Port Mapping Commands page 29 14 OmniSwitch CLI Reference Guide March 2011...
Страница 1942: ...show port monitoring file Port Mirroring and Monitoring Commands page 31 18 OmniSwitch CLI Reference Guide March 2011...
Страница 1960: ...show sflow poller sFlow Commands page 32 18 OmniSwitch CLI Reference Guide March 2011...
Страница 2014: ...show ethernet service sap profile VLAN Stacking Commands page 34 46 OmniSwitch CLI Reference Guide March 2011...
Страница 2114: ...show mac range alloc Chassis MAC Server CMS Commands page 39 8 OmniSwitch CLI Reference Guide March 2011...
Страница 2188: ...show command log status Session Management Commands page 41 36 OmniSwitch CLI Reference Guide March 2011...
Страница 2226: ...ftp File Management Commands page 42 38 OmniSwitch CLI Reference Guide March 2011...
Страница 2252: ...write terminal Configuration File Manager Commands page 44 18 OmniSwitch CLI Reference Guide March 2011...
Страница 2284: ...show snmp trap config SNMP Commands page 45 32 OmniSwitch CLI Reference Guide March 2011...
Страница 2294: ...show dns DNS Commands page 46 10 OmniSwitch CLI Reference Guide March 2011...
Страница 2350: ...OmniSwitch CLI Reference Guide March 2011 page 22 DNS Commands...