Description
Setting
The
Safety Network Number (SNN)
provides a unique network
identifier for each network in the safety system and is generated by
the safety PLC.
Note
The user should assign SNN numbers for each safety network or
safety sub-net that are unique system-wide.
SNN
CAUTION
Originators (scanners) having an automatic SNN setting feature, i.e.
automatically generated data and time, can only use this feature
when the safety system is not being relied upon and is not in safety
state.
The configuration signature, also called
Safety Configuration ID
(SCID)
, uniquely identifies the configuration of the
ABB CIP Safety
Adapter
and can be used to confirm the integrity of the adapter
configuration over time.
Configuration signa-
ture
The signature is checked whenever an originator tries to connect
to the adapter. If the signatures match, the connection is established.
If the signature does not match, the error response
Configuration
signature mismatch
is returned.
The signature is printed in the safety report and must be copied to
the safety scanner (PLC).
The following alternatives are provided:
•
Not used
- The configuration signature is not used.
•
Auto generated
- An automatically generated signature found
under
"Configuration Signature - Date"
,
"- Time"
, and
"- ID"
in the safety report.
•
User generated
- A user defined signature. Alternatively, the
user can manually write the signature encoded as a 10 bytes
long hexadecimal string in the text-box below. The signature
can then be found under
"Configuration Signature checksum"
in the safety report.
Note
When configuring safety connections without the configuration sig-
nature, i.e. not used, the user is responsible for ensuring that origin-
ators (scanners) and targets (adapters) have the correct configura-
tions.
Note
The configuration signature should only be considered verified after
user testing. User testing is the means by which all downloads are
validated.
Parameters for CIP Safety external adapter
Description
Setting
The same name as the system parameter
Name
in the type
Ether-
Net/IP Device
.
Name
The same size as the system parameter
Input Size
in the type
Eth-
erNet/IP IO Connection
.
Input size
Continues on next page
Application manual - Functional safety and SafeMove2
93
3HAC052610-001 Revision: P
© Copyright 2016-2020 ABB. All rights reserved.
4 The Visual SafeMove user interface in RobotStudio
4.6.2 Signals view
Continued
Содержание SafeMove2
Страница 1: ...ROBOTICS Application manual Functional safety and SafeMove2 ...
Страница 2: ...Trace back information Workspace 20C version a3 Checked in 2020 09 14 Skribenta version 5 3 075 ...
Страница 8: ...This page is intentionally left blank ...
Страница 16: ...This page is intentionally left blank ...
Страница 34: ...This page is intentionally left blank ...
Страница 56: ...This page is intentionally left blank ...
Страница 72: ...This page is intentionally left blank ...
Страница 112: ...This page is intentionally left blank ...
Страница 194: ...This page is intentionally left blank ...
Страница 196: ...This page is intentionally left blank ...
Страница 234: ...This page is intentionally left blank ...
Страница 237: ......