User authorization (UAS)
The following UAS settings related to the safety controller are available for setting
the user access on the FlexPendant.
For more information about creating user grants, see
.
Description
User grant
Required for changing to commissioning mode, see
.
Commissioning mode
Required for unlocking the keyless mode selector if the PIN-
code is lost or forgotten, see
Key-less mode selector
Required for locking the safety configuration.
Lock Safety Controller Config-
uration
Required for the following actions:
•
Loading a safety configuration.
•
Setting the safety configuration status to
Validated
.
•
Changing the operating mode of the safety controller
from the
Mode
tab.
Safety Services
Required for synchronizing the controller from the
Synchron-
ization
tab.
Software synchronization
The Configuration tab
The
Configuration
tab shows the status of the safety configuration file. From the
configuration tab it is possible to view the safety configuration, validate, and lock
the configuration file.
For more information, see
Validate the configuration on page 173
.
Description
Safety Config Status
When the safety technician has validated the configuration,
the status of the configuration is changed to
Validated
on
the FlexPendant.
Validated
When the safety responsible has approved the configuration,
the status of the configuration is changed to
Locked
on the
FlexPendant.
Locked
Tip
Tap the checksum to view the complete string in a larger window.
View safety controller data
Click the
View
button to view the safety configuration in a separate window.
The view function shows the safety configuration as it is defined in the xml-format,
which means that structure and function names etc. does not have a one-to-one
mapping with the configurator or the safety report.
For a more user friendly view, use RobotStudio to view configuration, or create a
new report.
Continues on next page
114
Application manual - Functional safety and SafeMove2
3HAC052610-001 Revision: P
© Copyright 2016-2020 ABB. All rights reserved.
5 The FlexPendant user interface
5.1 The
Safety Controller
control panel
Continued
Содержание SafeMove2
Страница 1: ...ROBOTICS Application manual Functional safety and SafeMove2 ...
Страница 2: ...Trace back information Workspace 20C version a3 Checked in 2020 09 14 Skribenta version 5 3 075 ...
Страница 8: ...This page is intentionally left blank ...
Страница 16: ...This page is intentionally left blank ...
Страница 34: ...This page is intentionally left blank ...
Страница 56: ...This page is intentionally left blank ...
Страница 72: ...This page is intentionally left blank ...
Страница 112: ...This page is intentionally left blank ...
Страница 194: ...This page is intentionally left blank ...
Страница 196: ...This page is intentionally left blank ...
Страница 234: ...This page is intentionally left blank ...
Страница 237: ......