If the safety module is used, the configured value for the parameter
Soft Superior
Stop
(
SoftSS
) is ignored and Superior Stop will always use a category 0 stop.
RAPID non motion execution
This test feature cannot fully be used together with the SafeMove option.
MultiMove
The safety module supports MultiMove systems with up to four robots.
The CPU load increases with more robots in a MultiMove system and can give
performance problems in combination with many zones and/or complex zones.
When experiencing performance problems, the event log message
90835
is
displayed. To reduce the CPU load, try to simplify the zones and use less zones.
The supported number of axes, ranges, and zones listed in section
is available for each robot in the MultiMove system.
Additional axes and robots that are monitored together, for instance a robot and
a track, must be physically connected to the same drive module.
Note
If a supervision function triggers a stop on one robot in a MultiMove system, then
all robots in the MultiMove system will be stopped.
Responsive jogging
Category 1 stop is deactivated in manual mode when responsive jogging is active.
This is because a robot that is stopped with a category 1 stop follows its
programmed path while decelerating. When using responsive jogging there is no
defined path available.
Note
Responsive jogging can be deactivated by changing the parameter
Jog Mode
from
Responsive
to
Standard
.
For more information about parameter
Jog Mode
, see type
Jog Parameters
, topic
Motion
in
Technical reference manual - System parameters
.
SoftMove
When SafeMove is used together with SoftMove there is a risk for servo lag
problems. The recommended action is to add a Contact Application Tolerance
(CAP) in the area where SoftMove is active.
For more information about SoftMove, see
Application manual - Spot options
and
Application manual - SoftMove
.
Application manual - Functional safety and SafeMove2
31
3HAC052610-001 Revision: P
© Copyright 2016-2020 ABB. All rights reserved.
1 Introduction
1.3 Limitations
Continued
Содержание SafeMove2
Страница 1: ...ROBOTICS Application manual Functional safety and SafeMove2 ...
Страница 2: ...Trace back information Workspace 20C version a3 Checked in 2020 09 14 Skribenta version 5 3 075 ...
Страница 8: ...This page is intentionally left blank ...
Страница 16: ...This page is intentionally left blank ...
Страница 34: ...This page is intentionally left blank ...
Страница 56: ...This page is intentionally left blank ...
Страница 72: ...This page is intentionally left blank ...
Страница 112: ...This page is intentionally left blank ...
Страница 194: ...This page is intentionally left blank ...
Страница 196: ...This page is intentionally left blank ...
Страница 234: ...This page is intentionally left blank ...
Страница 237: ......