6.23 Upgrading and installing new systems
Upgrading RobotWare
If an upgrade of RobotWare is done by using the Installation Manager, the safety
configuration is kept as it is. A restore of the safety configuration is not needed.
Since the configuration is kept as it is, the checksum is the same and the
configuration is automatically locked after upgrade.
Downgrading RobotWare
SafeMove is not forward compatible. A safety configuration from a newer system
is not possible to use in an older system.
Installing a new system
After installing a new system, or after a factory reset, the safety configuration is
empty and no safety functionality is active.
Use this procedure when installing a new system:
Action
Backup the old system.
1
Install the new system.
2
If the configuration was locked in the old system, there will be an error message
at startup.
Restore the backup and include the safety settings, see
3
Restart the system.
4
If the configuration was locked in the old system, then it will also be locked in the
new system.
Locked safety configurations
The safety configuration file in itself cannot be in locked state, it is the safety
controller hardware that is locked to a specific configuration. This has the following
implications on the system:
•
If a locked configuration is taken from one system and loaded into another
system, the configuration is not automatically locked in the new system.
•
If the configuration is locked to one system which is upgraded, the
configuration is automatically locked if it is loaded into the new system.
•
If two systems with different safety configurations are installed on one
controller, where one of the configurations is locked, the other system will
not be possible to use since the hardware is locked to the first system.
For information on locking the safety configuration, see
.
188
Application manual - Functional safety and SafeMove2
3HAC052610-001 Revision: P
© Copyright 2016-2020 ABB. All rights reserved.
6 Configuring SafeMove
6.23 Upgrading and installing new systems
Содержание SafeMove2
Страница 1: ...ROBOTICS Application manual Functional safety and SafeMove2 ...
Страница 2: ...Trace back information Workspace 20C version a3 Checked in 2020 09 14 Skribenta version 5 3 075 ...
Страница 8: ...This page is intentionally left blank ...
Страница 16: ...This page is intentionally left blank ...
Страница 34: ...This page is intentionally left blank ...
Страница 56: ...This page is intentionally left blank ...
Страница 72: ...This page is intentionally left blank ...
Страница 112: ...This page is intentionally left blank ...
Страница 194: ...This page is intentionally left blank ...
Страница 196: ...This page is intentionally left blank ...
Страница 234: ...This page is intentionally left blank ...
Страница 237: ......