The Encapsulate Upper Arm button
The
Encapsulate Upper Arm
button is used to create a geometry that encapsulates
the upper arm. The geometry can then be adapted to fit the needs of the current
application.
Up to two different geometries can be used to create a more accurate encapsulation
of the upper arm.
The Safe Zone button
The
Safe Zone
button is used to create safe zones. The safe zone is displayed in
the graphics window as a rectangular box with vertices.
Description
Button
Creates a default safety zone in the shape of a rectangular box.
Safe Zone
Crates a safe zone by wrapping a part in the RobotStudio station.
The part must first be selected.
Wrapped Safe Zone
After a zone has been created, the next step is to add safety functions to the zone.
This is described in section
.
Tip
It is recommended to change the default name of the safe zone in the
Visual
SafeMove
browser to a name that better corresponds to the current installation.
Settings
The following settings are available in the
Visual SafeMove Properties
browser
after the zone has been created.
Description
Setting
Used to set the priority for overlapping zones. The zone with the
highest priority will set the speed limit for the overlapping space.
•
BASE
- lowest priority.
•
NORMAL
- normal priority.
•
OVERRIDE
- highest priority.
For more information, see
Configure the zones on page 155
.
Tip
Create a
BASE
zone with a low speed limit that covers the entire
robot cell. This zone is then used to protect the fence. Add
NORMAL
zones for the areas where the robot performs most of the work.
Additionally, add
OVERRIDE
zones for any areas where the robot
is allowed to move fast.
Tool Speed Supervi-
sion Priority
The reference coordinate system in the RobotStudio station.
Note
The base frame cannot be used for reference if it is rotated around
the controller world x or y-axes, for example when using a tilted ro-
bot.
Reference
The height of the zone.
Height
Continues on next page
80
Application manual - Functional safety and SafeMove2
3HAC052610-001 Revision: P
© Copyright 2016-2020 ABB. All rights reserved.
4 The Visual SafeMove user interface in RobotStudio
4.3.2 Adding SafeMove functions
Continued
Содержание SafeMove2
Страница 1: ...ROBOTICS Application manual Functional safety and SafeMove2 ...
Страница 2: ...Trace back information Workspace 20C version a3 Checked in 2020 09 14 Skribenta version 5 3 075 ...
Страница 8: ...This page is intentionally left blank ...
Страница 16: ...This page is intentionally left blank ...
Страница 34: ...This page is intentionally left blank ...
Страница 56: ...This page is intentionally left blank ...
Страница 72: ...This page is intentionally left blank ...
Страница 112: ...This page is intentionally left blank ...
Страница 194: ...This page is intentionally left blank ...
Страница 196: ...This page is intentionally left blank ...
Страница 234: ...This page is intentionally left blank ...
Страница 237: ......