
8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-580
4969
CONVTR POWER
ERR(FREQUENCY
(SV)
Board or software
failure
Reset the alarm, and then execute the job.
If the error occurs again, replace the YSV01 board and the YCP01 board,
and then execute the job. Or replace the YIF01 board, and then initialize the
job. Then, load the data saved in the external memory device and execute
the job again.
4970
CONVTR POWER
ERR(PHASE
SEQ.)(SV)
Primary power
supply failure
Correct the converter primary power supply.
4971
CONVTR POWER
ERR(PEAK)(SV)
Primary power
supply failure
Correct the converter primary power supply.
4972
CONVTR
REGENERATE
OVERLOAD(SV)
Primary power
supply failure
Correct the converter primary power supply.
4973
POSITION
ERROR(COLLISIO
N DETECT)
Setting error
Check the deceleration time parameter.
4980
DESTINATION
PULSE LIMIT
Setting error
(1)Check the following settings.
·Check the position setting for the step (move instruction) where the alarm
occurred.
4981
DEST PULSE
MECHANICAL
LIMIT
Setting error
(1)Check the following settings.
·Check the position setting for the step (move instruction) where the alarm
occurred.
4982
DEST
MECHANICAL
INTRF
Setting error
(1)Check the following settings.
·Check the position setting for the step (move instruction) where the alarm
occurred.
4983
DEST
MECHANICAL
INTRF
Setting error
(1)Check the following settings.
·Check the position setting for the step (move instruction) where the alarm
occurred.
4984
DESTINATION
SELF-
INTERFERENCE
Setting error
(1)Check the following settings.
·Check the position setting for the step (move instruction) where the alarm
occurred.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy