8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-92
YCP01 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
remove the CF from the failure YCP01 board to insert it into the new YCP01
board.
YIF board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF01 board, and then load
the CMOS.BIN saved before alarm occurred.
0600
MEDAR STATUS
ERROR
MADER timer error
Refer to the instruction manual for the MEDAR function.
0601
MEDAR
DIAGNOSIS
ERROR
MADER timer error
Refer to the instruction manual for the MEDAR function.
0602
MEDAR VERSION
ERROR
MADER timer error
Refer to the instruction manual for the MEDAR function.
0603
MEDAR REVISION
ERROR
MADER timer error
Refer to the instruction manual for the MEDAR function.
0604
MEDAR MODE
CHANGE ERROR
MADER timer error
Refer to the instruction manual for the MEDAR function.
0605
MEDAR
SCHEDULE
TRANSMIT
ERROR
MADER timer error
Refer to the instruction manual for the MEDAR function.
0606
MEDAR ERROR 1
MADER timer error
Refer to the instruction manual for the MEDAR function.
0607
MEDAR ERROR 2
MADER timer error
Refer to the instruction manual for the MEDAR function.
0608
MEDAR WELDER
TYPE MISMATCH
MADER timer error
Refer to the instruction manual for the MEDAR function.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy