8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-296
12
The data for the vision execution
command is incorrect.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
4125
TRANS
ERROR(WELD
PULSE COND)
1
File access error
Communication
error
(1)Reset the alarm.
(2)If the alarm occurs again, check the communication setting and
communication wiring is correct.
2
File data error
Communication
error
(1)Reset the alarm.
(2)If the alarm occurs again, check the setting of communication or file data
is correctly set.
3
Calibration execution error
Communication
error
(1)Reset the alarm.
(2)If the alarm occurs again, check the setting of communication or
transmission side data is correctly set.
4
YCP01 port initialize error
Communication
error
(1)Reset the alarm.
(2)If the alarm occurs again, check the setting of communication or YCP01
port is correctly set.
5
Time-out occurred during data
transmission.
Communication
error
(1)Reset the alarm.
(2)If the alarm occurs again, check the communication setting and
communication wiring is correct.
6
Time-out occurred during data
reception.
Communication
error
(1)Reset the alarm.
(2)If the alarm occurs again, check the communication setting and
communication wiring is correct.
7
Receive data error
Communication
error
(1)Reset the alarm.
(2)If the alarm occurs again, check the communication setting and
communication wiring is correct.
8
Coordinate conversion error
Communication
error
(1)Reset the alarm.
(2)If the alarm occurs again, check the setting of communication or
transmission side data is correctly set.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy