8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-116
0917
CPU
ERROR(YCP02#7)
An error was detected in the CPU. Setting error
(1)Check the following settings.
· Optional board in maintenance mode
Board failure
(YCP02 board)
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the following board. Save the
CMOS.BIN before replace the board to be safe.
· YCP02 board
0918
CPU
ERROR(YCP02#8)
An error was detected in the CPU. Setting error
(1)Check the following settings.
· Optional board in maintenance mode
Board failure
(YCP02 board)
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the following board. Save the
CMOS.BIN before replace the board to be safe.
· YCP02 board
0920
BUS
ERROR(YCP01)
1
The JL chip does not operate
normally.
YCP01 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
remove the CF from the failure YCP01 board to insert it into the new YCP01
board.
YIF board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF01 board, and then load
the CMOS.BIN saved before alarm occurred.
0950
CPU
ERROR(EAXA#1)
An error was detected in the CPU
of servo board #1.
Connection failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connection and insertion of the
following cables and connectors.
· The cable of EAXA board CN509
· The cable of EAXA board connector CN515/516
· The PCI connector of the YIF01 board
· The cable of YIF board connector CN113
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy