8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-219
2
The servo float function was used
for the axis for which the axis
endless function was enabled.
The servo float function cannot be
used for the axis which the axis
endless function was enabled.
Setting error
Disable either the axis endless function or the servo float function of
corresponding axis.
3
The encoders manufactured by
Tamagawa Seiki Co., Ltd. was
used for the axis for which the axis
endless function was enabled.
The encoders manufactured by
Tamagawa Seiki Co., Ltd. cannot
be used for the axis which the axis
endless function was enabled.
Setting error
Disable the corresponding axis endless function.
4
The general servo function was
used for the axis for which the axis
endless function was enabled.
The general servo function cannot
be used for the axis which the axis
endless function was enabled.
Setting error
Disable the corresponding axis endless function.
1658
REDUCTION
STOP SPECIFIC.
ERR(SV)
1
The servo float function was used
for the axis for which the
deceleration stop function was
enabled.
The servo float function cannot be
used for the axis which the
deceleration stop function was
enabled.
Setting error
Check the JOB.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy