8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-571
Connection failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, check the connection and inserting state of the
following cables and connectors.
·The motor power line
·The encoder line
Module
failure(motor)
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the motor.
4865
POSITION
ERROR(SERVO2)
Module
failure(SERVOPACK
)
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the SERVOPACK.
Setting error
Check the settings for manipulator motion condition (influence by external
force, load condition).
Connection failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, check the connection and inserting state of the
following cables and connectors.
·The SERVOPACK motor power line connector
·The power cable connection of the manipulator cable.
4866
OPEN
PHASE(SERVO2)
Connection failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, check the connection and inserting state of the
following cables and connectors.
·The SERVOPACK motor power line connector
·The power cable connection of the manipulator cable.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy