DX100
8.3
A
la
rm Me
ssa
ge List
8-514
60
Zero or a negative value is set for
the sphere at the arm interference
check point.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
61
Zero or a negative value is set for
the cylinder at the arm interference
check point.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
62
The number of designated check
points for the arm interference
check is insufficient.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
70
All of X, Y, and Z value of the
expanded check-point 1 for the
arm interference check are set to
zero.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
71
All of X, Y, and Z value of the
expanded check-point 2 for the
arm interference check are set to
zero.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
85
The setting of wrist axis angle for
tube-incorporated wrist type
manipulators or three-roll wrist
type manipulators is incorrect.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
86
The special link JOG operation
cannot be used with this
manipulator.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy