8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-181
1307
ENCODER TYPE
MISMATCH
Sub Code: Signifies the axis in
which the alarm occurred
Setting error
(1)Check the following settings.
·Check the motor type before and after the replacement.
· When the external axis is mounted, check if there is no difference between
the motor selected at configuration and the motor that is actually mounted.
Module
failure(encoder)
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the encoder.
Software operation
error occurred
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
1308
CONVERTER
TYPE MISMATCH
Sub Code: Signifies the converter
in which the alarm occurred
Setting error
(1)Check the following settings.
· Check the current capacity of the amplifier before/after replacement by the
model described in board.
· When the external axis is mounted, check if there is no difference between
the converter selected at configuration and the converter that is actually
mounted.
Reference parameter: after SVCxB040
Module
failure(converter)
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connection and insertion of the
following cables and connectors.
· The MII communications cable which I/O module of the corresponding sub
code
· (In case of MII communications last station) Terminator
· 24V power of the corresponding I/O module
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy