8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-289
17
PWAIT instruction is the old
specification.
Setting error
(1)Check the following settings.
·The specifications of PWAIT instruction
Register the PWAIT instruction as new specification.
4104
WRONG
EXECUTION OF
LOAD INST
Sub Code1 to 245: Signifies the
data transmission error.
Setting error
* Refer to the instruction manual for Data Transmission Function for details.
4105
WRONG
EXECUTION OF
SAVE INST
Sub Code1 to 245: Signifies the
data transmission error.
Setting error
* Refer to the instruction manual for Data Transmission Function for details.
4106
WRONG
EXECUTION OF
DELETE INST
Sub Code1 to 245: Signifies the
data transmission error.
Setting error
* Refer to the instruction manual for Data Transmission Function for details.
4107
OUT OF
RANGE(ABSO
DATA)
Setting error
(1)Check the following settings.
·Move the manipulator or station to the zero position by the axis operation
and check the home position alignment marks (the arrow).
4109
DC 24V POWER
SUPPLY
FAILURE(I/O)
0000_0001: Fuse blown (YIU unit)
0000_0011: External 24V power
supply error.
Connection failure
(1)Reset the alarm.
(2)If the alarm occurs again, check the connection and inserting state of the
following cables and connectors.
Check the insertion and connection of the followings.
·Fuse (blown) of YIU unit
·The communications cable for the I/O module
Voltage error
(1)Reset the alarm.
(2)If the alarm occurs again, Check the 24V external power supply. If
abnormal, replace the 24V external power supply.
Overrun limit switch
released
Check that the overrun limit switch is not activating. If overrun limit switch is
activating, return to a normal position.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy