YCP01 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
remove the CF from the failure YCP01 board to insert it into the new YCP01
board.
YIF board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF01 board, and then load
the CMOS.BIN saved before alarm occurred.
1
The job files are damaged.
Data error
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, initialize the job file in maintenance mode, and
then load the data (job, variable data, Robot calibration data) saved in the
external memory device.
YCP01 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
remove the CF from the failure YCP01 board to insert it into the new YCP01
board.
YIF board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF01 board, and then load
the CMOS.BIN saved before alarm occurred.
2
The management data of position
data files are damaged.
Data error
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, initialize the job file in maintenance mode, and
then load the data (job, variable data, Robot calibration data) saved in the
external memory device.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy