8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-395
-10
The sampling data is destroyed.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
-11
Data in control process for
memory play file is incorrect.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
-12
The sampling data is scanned only
at top or end position.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
-13
The memory play file system is not
initialized.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
-14
The offset value is out of range at
sampling data scanning.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
4225
OVER
SPEED(YCP01)
Signifies the control axis number
which detected an error
Setting error
(1)Check the following settings.
·The gun electrode hits the welded target distance of motor gun
·manipulator motion (external force, gravity)
Connection failure
(1)Reset the alarm.
(2)If the alarm occurs again, check the connection and inserting state of the
following cables and connectors.
·The motor power line
·The encoder line
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy