8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-333
An error occurred in parameter
specifications for the access to a
job .
Software operation
error occurred
(1)Reset the alarm.
(2)If you edit this job, release the prohibition.
(3)If the error occurs again, delete the job where the alarm occurred.
(4)If the error occurs again after the previous measures were executed,
initialize the job file in the maintenance mode, and then load the saved job
file.
(5)If the error occurs again though the previous measures were executed,
save the CMOS.BIN in maintenance mode, and then contact your Yaskawa
representative about occurrence status (operating procedure).
10
An error occurred in job data
control system.
Software operation
error occurred
(1)Reset the alarm.
(2)If the error occurs again, delete the job where the alarm occurred.
(3)If the error occurs again after the previous measures were executed,
initialize the job file in the maintenance mode, and then load the saved job
file.
(4)If the error occurs again though the previous measures were executed,
save the CMOS.BIN in maintenance mode, and then contact your Yaskawa
representative about occurrence status (operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy