8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-8
YCP01 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
remove the CF from the failure YCP01 board to insert it into the new YCP01
board.
YIF board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF01 board, and then load
the CMOS.BIN saved before alarm occurred.
50
No response was sent from the
servo board #1 when the control
power turned ON.
At this time, the DX100 may judge
it as signal input such as external
hold wrong. However, it is caused
by the communication error with
servo baord #1. Therefore,
execute the following measures
first of all.
Setting error
(1)Check the following settings.
· Control group settings in maintenance mode
· The EAXA board rotary switch setting (0) of the corresponding node
number (SV#1)
Connection failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connection and insertion of the
following cables and connectors.
· CN509 cable of EAXA board
· The cable of EAXA board connector CN515/516
· The PCI connector of the YIF01 board
· The cable of YIF board connector CN113
EAXA board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the EAXA board. Save the CMOS.BIN
before replace the board to be safe.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy