8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-495
6
When the timer mode is specified
in the weaving file, a negative
value is set for the timer value.
Setting error
(1)Check the following settings.
·Set a positive value for the timer value.
7
For triangle or L-type weaving,
zero is set for the vertical or
horizontal distance.
Setting error
(1)Check the following settings.
·Set a positive value for the vertical and horizontal distance.
8
The coordinate control axis
designation for the reference point
is different from actual control axis.
Setting error
(1)Check the following settings.
·Match the control group designation of the wall point and weaving execution.
9
The distance between the point P
and the TCP could not be
calculated in wrist weaving.
Setting error
(1)Check the following settings.
·Set the correct dimensions in the tool data.
10
The distance between the point P
and the TCP could not be
calculated in circular wrist
weaving.
Setting error
(1)Check the following settings.
·Set the correct dimensions in the tool data.
11
The Y-direction element of circular
coordinate system for circular wrist
weaving could not be calculated.
Setting error
(1)Check the following settings.
·Check the settings for wall and horizontal direction.
12
The X-direction element of circular
coordinate system for circular wrist
weaving could not be calculated.
Setting error
(1)Check the following settings.
·Check the settings for wall and horizontal direction.
14
Weaving basic-orientation
calculation error
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
15
Calculation error of horizontal- and
wall-direction vector for weaving
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy