8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-268
4037
MEMORY
ERROR(STROKE
POSITION)
Sub Code: File number
Data error
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the FULL/SHORT OPEN position
setting file in maintenance mode, and then load the FULL/SHORT OPEN
position setting file saved in the external memory device.
YCP01 board failure (1)Reset the alarm.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
insert the CF card which inserted original YCP01 board into the new YCP01
board.
YIF board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YIF board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF board, and then load
the CMOS.BIN saved before alarm occurred.
4038
MEMORY
ERROR(PRESSUR
E FILE)
Sub Code: File number
Data error
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the dry-spotting pressure file in
maintenance mode, and then load the dry-spotting pressure file saved in the
external memory device.
YCP01 board failure (1)Reset the alarm.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
insert the CF card which inserted original YCP01 board into the new YCP01
board.
YIF board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YIF board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF board, and then load
the CMOS.BIN saved before alarm occurred.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy