8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-332
7
A job that did not exist in the
memory was specified.
Software operation
error occurred
(1)Reset the alarm.
(2)If the error occurs again, delete the job where the alarm occurred.
(3)If the error occurs again after the previous measures were executed,
initialize the job file in the maintenance mode, and then load the saved job
file.
(4)If the error occurs again though the previous measures were executed,
save the CMOS.BIN in maintenance mode, and then contact your Yaskawa
representative about occurrence status (operating procedure).
8
An attempt was made to change
the contents for the job prohibited
from being edited.
Setting error
(1)Check the following settings.
·Setting of EDIT LOCK in JOB header screen
If the job is protected from editing, release the prohibition.
Software operation
error occurred
(1)Reset the alarm.
(2)If you edit this job, release the prohibition.
(3)If the error occurs again, delete the job where the alarm occurred.
(4)If the error occurs again after the previous measures were executed,
initialize the job file in the maintenance mode, and then load the saved job
file.
(5)If the error occurs again though the previous measures were executed,
save the CMOS.BIN in maintenance mode, and then contact your Yaskawa
representative about occurrence status (operating procedure).
9
An attempt was made to change
the contents for the job prohibited
from being edited.
Setting error
(1)Check the following settings.
·Setting of EDIT LOCK in JOB header screen
If the job is protected from editing, release the prohibition.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy