8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-557
3
An attempt was made to
disconnect a control group other
than the occupation control group
when executing a PSTART
instruction.
Setting error
(1)Check the following settings.
·Check the settings for PSTART instruction.
4641
CANNOT
EXECUTE
JOB(SEPARATE
GRP)
Sub Code: The disconnected
control group used by a move
instruction
Setting error
(1)Check the following settings.
·Correct the teaching so that the control group disconnected by itself is not to
operate for move instruction of own system.
4644
SPOT WELDER I/F
ERROR(ASW)
8
The controller could not send an
instruction to the welder because
the welder was busy in processing.
Connection failure
(1)Reset the alarm.
(2)If the alarm occurs again, check the connection and inserting state of the
following cables and connectors.
·DENGENSHA welding I/F board
·NADEX DeviceNet cable
9
Welding current error at welding is
completed successfully.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
10
Abnormal code error at welding is
completed successfully.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
11
Welding command process
exceptional error
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
102
The specified welder number
(system) could not be found.
Setting error
(1)Check the following settings.
·Confirm the specified welder number (system) and the setting.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy