8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-297
9
Position type variable access error Communication
error
(1)Reset the alarm.
(2)If the alarm occurs again, check the setting of communication or
transmission side data is correctly set.
10
Failed to store the area.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
11
Measurement item setting error
Communication
error
(1)Reset the alarm.
(2)If the alarm occurs again, check the setting of communication or
transmission side data is correctly set.
12
Tag setting error
Communication
error
(1)Reset the alarm.
(2)If the alarm occurs again, check the setting of communication or
transmission side data is correctly set.
48
Wait status table FULL
Communication
error
(1)Reset the alarm.
(2)If the alarm occurs again, check the setting of communication or
transmission side data is correctly set.
4126
CANNOT
EXECUTE AUTO
PMT
1
System error
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
2
PBOX cannot be edited.
Setting error
(1)Check the following settings.
·I/O status of the edit prohibit signal
The edit prohibit signal cannot input.
3
The source job cannot be edited.
Setting error
(1)Check the following settings.
·The prohibit status of source job
If the source job is protected from editing, it cannot be edited.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause