8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-172
Connection failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, check the connection and insertion of the
following cables and connectors.
[Robot axis]
· Cable between encoders
· EAXA-CN508
[External axis]
· Cable between encoders
· EAXB-CN0534,535,536
1300
SERVO CPU
SYNCHRONIZING
ERROR
Connection failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, check the connection and insertion of the
following cables and connectors.
· EAXA01-CN515
· YIF01-CN113
EAXA board failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the EAXA board. Save the CMOS.BIN
before replace the board to be safe.
1301
COMMUNICATION
ERROR(SERVO)
0
Communication status error
Connection failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, check the connection and insertion of the
following cables and connectors.
· EAXA01-CN515
· YIF01-CN113
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy