8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-299
8
The job under execution is
specified as the conversion job.
Setting error
(1)Check the following settings.
·Execution status of the source job
·Execution status of the converted job
The job under execution is specified for the source / converted job. Execute
conversion operation after ending the job execution.
4128
ARC MONITOR
ERROR
1
Monitor ON was executed in
Monitor ON.
Setting error
(1)Check the following settings.
·Arc monitor ON status
Arc monitor ON cannot be executed during arc monitor ON.
10
Analog CH specification or register
specification is not exist.
Setting error
(1)Check the following settings.
·Analog CH specification
·Register specification
Analog CH specification or register specification is required.
11
The number of samplings exceeds
the set value.
Setting error
(1)Check the following settings.
·The number of samplings
The number of sampling is too much. Confirm the monitor ON/OFF status.
4129
TWIN DRIVE OUT
OF
RANGE(START)
Sub Code: Corresponding master-
axes and slave-axes are displayed
by the bit.
Setting error
(1)Check the following settings.
·Pulse error of the master-axes and the slave-axes
Switch to independent movement mode so that the pulse error of the master-
axes and the slave-axes is settled within allowable range.
4130
NETWORK
APPLICATION
PROCESS ERROR
1
An error occurred when the
notification of the APP task re-
initialization was processed in the
Ethernet function.
Software operation
error occurred
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy