8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-419
Module
failure(Regenerative
resistor)
Replace the regenerative resistor.
Module
failure(converter)
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the SERVOPACK.
EAXA board failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the EAXA board. Save the CMOS.BIN
before replacing the board to be safe.
Overloading
Check that the load does not exceed the allowable limit.
4335
GROUND FAULT
Sub Code: Signifies the physical
No. of converter in which the alarm
occurred
Connection failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, check the connection and inserting state of the
following cables and connectors.
·EAXA01-CN507,510
·EAXB01-CN08
·Converter CN551,553
Connection failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the following cables.
·Manipulator cable
·Supply cable
Module
failure(motor)
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the motor.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy