POWER LOST
DETECTION(EAXA
01/02)
Instant power failure Check if the primary power supply voltage is dropping.
1350
POWER ON UNIT
TYPE MISMATCH
1352
SERIAL
ENCODER
CORRECTION
ERROR
Sub Code: Signifies the axis in
which the alarm occurred
Connection failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, check the connection and insertion of the
following cables and connectors.
[Robot axis]
· Cable between encoders
· EAXA-CN508
[External axis]
· Cable between encoders
· EAXB-CN0534,535,536
Connection failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, check the connection and insertion of the
following cables and connectors.
[Robot axis]
· Cable between encoders
· EAXA-CN508
[External axis]
· Cable between encoders
· EAXB-CN0534,535,536
Module
failure(encoder)
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the encoder.