8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-255
4005
MEMORY
ERROR(SECOND
HOME POS)
Data error
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the second home positioning file in
maintenance mode, and then load the second home positioning file saved in
the external memory device.
YCP01 board failure (1)Reset the alarm.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
insert the CF card which inserted original YCP01 board into the new YCP01
board.
YIF board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YIF board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF board, and then load
the CMOS.BIN saved before alarm occurred.
4006
MEMORY
ERROR(POWER
SOURCE COND)
Sub Code: Page number
Data error
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the arc welding Power Source condition
file in maintenance mode, and then load the arc welding Power Source
condition file saved in the external memory device.
YCP01 board failure (1)Reset the alarm.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
insert the CF card which inserted original YCP01 board into the new YCP01
board.
YIF board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YIF board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF board, and then load
the CMOS.BIN saved before alarm occurred.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy