8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-222
1670
GENERAL SERVO
SETTING ERROR
(SV)
EAXA board failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the EAXA board. Save the CMOS.BIN
before replace the board to be safe.
1671
GENERAL SV
ALARM CODE
ERROR (SV)
EAXA board failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the EAXA board. Save the CMOS.BIN
before replace the board to be safe.
1672
GRP CHANGE PG
POWER ON ERR
(SV)
Sub Code: Signifies the axis in
which the alarm occurred
Setting error
Check the JOB.
1673
GRP CHANGE
SERVO ON
ERROR (SV)
Sub Code: Signifies the axis in
which the alarm occurred
Setting error
Check the JOB.
1674
CTRL LAW
SWITCHING
ORDER ERR (SV)
EAXA board failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the EAXA board. Save the CMOS.BIN
before replace the board to be safe.
1675
BASE BLOCK
READ SIGNAL
ERR (SV)
EAXA board failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the EAXA board. Save the CMOS.BIN
before replace the board to be safe.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy