8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-284
4073
MEMORY
ERROR(LASER
TRACKING SET
FILE)
Data error
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the laser tracking welding set file in
maintenance mode, and then load the laser tracking welding set file saved in
the external memory device.
YCP01 board failure (1)Reset the alarm.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
insert the CF card which inserted original YCP01 board into the new YCP01
board.
YIF board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YIF board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF board, and then load
the CMOS.BIN saved before alarm occurred.
4074
MEMORY
ERROR(LASER
TRACKING
TRACK SET FILE)
Data error
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the laser tracking track set file in
maintenance mode, and then load the laser tracking track set file saved in
the external memory device.
YCP01 board failure (1)Reset the alarm.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
insert the CF card which inserted original YCP01 board into the new YCP01
board.
YIF board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YIF board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF board, and then load
the CMOS.BIN saved before alarm occurred.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy