8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-533
4578
SPOT WELD
ERROR
Sub Code: Welder number
Setting error
(1)Check the following settings.
·Check the settings for the timer conductor where the welding error occurred.
4579
ANTICIPATION
CONTROL ERROR
1
No availability in anticipation
control
Setting error
(1)Check the following settings.
·Maximum simultaneous execution number of anticipation control is five.
Correct the settings for the job so that it is within five.
2
The anticipation data exceeded
the maximum length.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
4580
ANTICIPATION
DISTANCE NOT
ENOUGH
Setting error
(1)Check the following settings.
·Operate the manipulator to the start position of the step where the alarm
occurred, and then re-execute.
4581
DEFECTIVE
ANTICIPATION OT
FILE
1
Incorrect setting of OT output
number for anticipation output file
Setting error
(1)Check the following settings.
·Check the setting value of OT output number.
2
Incorrect setting of OG output
number for anticipation output file
Setting error
(1)Check the following settings.
·Check the setting value of OG output number.
4583
CANNOT
EXECUTE GUN
TYPE
Setting error
(1)Check the following settings.
·Check the settings for the motion mode set to the gun.
4584
STRWAIT TIME
LIMIT
Setting error
(1)Check the following settings.
·Check the cause such as defective limit switch.
4585
SERVO PG ON
ERROR
Connection failure
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, check the connection and inserting state of the
following cables and connectors.
·Each axes encoder cable
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy