8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-556
4635
CANNOT
EXECUTE
COMMON JOB
Sub Code: The related control-
group
Setting error
(1)Check the following settings.
·Check the settings for control group specified by the CALL instruction.
4636
THICKNESS
ERROR
Sub code: Gun number
Setting error
(1)Check the following settings.
·Weld the spot by thickness within allowable range.
4637
TRACK CHG
WORK IN/NOT
NOT FOUND
Sub Code: Conveyor characteristic
file number
Setting error
(1)Check the following settings.
·Check the workpiece presence/absence and data settings for the
synchronization section.
4638
TRACKING CHG
WORK ID NOT
FOUND
Sub Code: Conveyor characteristic
file number
Setting error
(1)Check the following settings.
·Check the workpiece presence/absence and data settings for the
synchronization section.
4639
SYMOVJ INST
EXECUTE ERROR
2
The conveyor moving amount is
not specified for the SYMOVJ
motion.
Setting error
(1)Check the following settings.
·Set the conveyor moving amount for the SYMOVJ motion.
3
An error occurred in the
preparation process of the
manipulator motion start position
for the SYMOVJ motion.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
4
An error occurred in the
preparation process of the
manipulator motion end position
for the SYMOVJ motion.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
4640
WRONG
EXECUTION OF
PSTART INST
1
No axis data of control group to be
disconnected
Setting error
(1)Check the following settings.
·Check the settings for PSTART instruction.
2
An attempt was made to
disconnect a control group other
than the occupation control group
during prereading processing.
Setting error
(1)Check the following settings.
·Check the settings for PSTART instruction.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause