8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-417
XEI01 board failure
1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connection and inserting state of the
following cables and connectors.
·XEI01 board
COV03 board failure 1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connection and inserting state of the
following cables and connectors.
·COV03 board
EAXA board failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the EAXA board. Save the CMOS.BIN
before replacing the board to be safe.
Connection failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the following cables.
·Cable between the EAXB01 board and XEI01 board
4330
BROKEN SPEED
MONITOR LINE
Connection failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, check the connection and inserting state of the
following cables and connectors.
·Speed monitor unit
4331
SPEED MONITOR
LEVEL ERROR
EAXA board failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the EAXA board. Save the CMOS.BIN
before replacing the board to be safe.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy