1
Equipment Configuration
DX100
1.1
Arrangement of Units and Circuit Boards
1-1
1
Equipment Configuration
The DX100 is comprised of individual units and modules (circuit boards).
Malfunctioning components can generally be easily repaired after a failure
by replacing a unit or a module. This section explains the configuration of
the DX100 equipment.
1.1
Arrangement of Units and Circuit Boards
1.1.1
Arrangement
The arrangements of units and circuit boards in small-capacity, medium-
capacity, and large-capacity DX100s are shown.
1.1.1.1
Small-Capacity DX100 Controller
Fig. 1-1: Configuration of Small Capacity DX100 -A Controller (Standard)
FAN1
FAN2
FAN
CN152
1
R-IN
R-INCOM
2
R-OUT
3
R-OUTCOM
4
FAN1
FAN2
FAN
CN152
1
R-IN
R-INCOM
2
R-OUT
3
R-OUTCOM
4
A
0
1
2FU
FU
A
0
1
1
5A125V
3FU
5A125V
4FU
CN601
CN610
CN611
CN607
CN107
SVMX2
CN601
CN606
CN612
CN608
CN602
CN603
CN604
CN605
V
U
T
S
R
Q
P
N
M
L
K
J
H
G
F
E
D
C
B
A
30
29
28
27
26
14
25
24
23
22
21
20
19
18
17
16
15
13
12
11
10
09
08
07
06
05
04
03
02
01
C90AD XXXXX
MADE IN JAPAN
Fuji Electric Hi-Tech .
DATE
NO.
POWER SUPPLY
CPS-520F
YYYY-MM
V
U
T
S
R
Q
P
N
M
L
K
J
H
G
F
E
D
C
B
A
30
29
28
27
26
14
25
24
23
22
21
20
19
18
17
16
15
13
12
11
10
09
08
07
06
05
04
03
02
01
CN158/159
CN154/155
(+24V1/V2)
(+24V2)
CN156/157
(+24V3)
CN153
(REMOTE)
CN152
(+5V/ALM)
SOURCE
OHT
INPUT
FAN
+24V
+5V
P-ON
50/60Hz
(AC IN)
CN151
200-240V AC
3.4A-2.8A
FUSE
CN215
CN216
CN208
CN209
CN210
CN211
CN212
CN213
C
N214
CN200
CN201
CN202
CN203
C
N204
CN205
CN206
CN207
A
B
1
A
B
1
FRC5-C50S52T-OLS(D20)
A
B
1
PE
GSOUTFB2-
G
GSOUT2-
GSOUTFB1-
G
GSOUT1-
+24V2
+24V2
+24V2
024V2
024V2
024V2
EXDSW2-
EXDSW1-
EXHOLD-
SSP+
EXSVON-
SSP-
FST2-
FST2+
FST1-
FST1+
EXESP2-
EXESP1-
SYSRUN-
SAFF2-
SAFF2+
SAFF1-
SAFF1+
GSIN22-
GSIN21-
GSIN12-
GSIN11-
MXT
NJ2959-1
50
49
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
A’
A
SVMX2
SVMX1
CN603
CN604
CN605
CN606
NCM
CN607
CN611
4FU
3FU
2FU
1FU
CN610
CN601
CN609
CN608
CN602
A-A’ Section
Inside View of F Door
Front View
Inside the Controller
Brake board
JANCD-YBK01-1E
I/O Unit
JZNC-YIU01-E
Machine safety unit
JZNC-YSU01-1E
Robot I/Fcircuit board
JANCD-YIF01-1
JZNC-YRK01-1E
JZNC-YPS01-E
CPS Unit
NF32-SW
Breaker
SVMX1
CN612
Covering plate
Power supply
contractor unit
JZRCR-YPU01-1
Backside duct fan:
4715MS-22T-B50-B00
(For air inlet)
Regenerative resistor:
MRC22-125K-220W-12.5
(220W,12.5
)
SERVOPACK:
Refer to the
following table.
Back View
(without cover)
Emergency stop
button:
HW1B-V404R
CPU unit:
Interior circulation fan:
4715MS-22T-B50-B00
(For air inlet)
(MXT)
Robot system
specified input
terminal block
Model
DX100
SERVOPACK (Converter Integrated)
MH5L
ERDR-MH0005L-A00
SRDA-MH5
MH6
ERDR-MH00006-A00
SRDA-MH6
MA1400
ERDR-MA01400-A00
SRDA-MH6
VA1400
ERDR-VA01400-A00
JZRCR-MH6-14/00
1)
MA1900
ERDR-MA01900-A00
SRDA-MH20
HP20D
ERDR-HP0020D-A00
SRDA-MH20
HP20D-6
1SRDA-MH6+SRDA-SRDA-SDA14A01A-E