9.19 Defaults by Bypass and Drive Model
690
YASKAWA
SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference
No.
Name
Unit
Default
-
Drive Model
-
D114
A104
D143
A130
D169
A154
D211
A192
D273
A248
o2-04
Drive Model (KVA)
Selection
Hex.
70
72
73
74
75
E2-11
Motor Rated
Power
HP
(kW)
40
(30)
50
(37)
60
(45)
75
(55)
100
(75)
E2-02
Motor Rated Slip
Hz
1.80
1.33
1.60
1.43
1.39
E2-03
Motor No-Load
Current
A
21.9
38.2
44.0
45.6
72.0
E2-05
Motor Line-to-Line
Resistance
Ω
0.064
0.039
0.030
0.022
0.023
E2-06
Motor Leakage
Inductance
%
20.8
18.8
20.2
20.5
20.0
E2-10
Motor Iron Loss
W
699
823
852
960
1200
L2-02
Power Loss Ride
Through Time
s
2.0
2.0
2.0
2.0
2.0
L2-03
Minimum Baseblock
Time
s
1.1
1.1
1.2
1.3
1.5
L2-04
Powerloss V/f
Recovery Ramp
Time
s
0.6
0.6
1
1
1
L2-05
Undervoltage
Detection Lvl (Uv1)
-
190
190
190
190
190
L3-24
Motor Accel Time
for Inertia Cal
s
0.323
0.32
0.387
0.317
0.533
L8-02
Overheat Alarm
Level
°C
115
110
110
110
110
L8-09
Output Ground Fault
Detection
-
1
1
1
1
1
L8-35
Installation Method
Selection
-
2
2
2
0
0
L8-38
Carrier Frequency
Reduction
-
2
2
2
2
2
n1-01
Hunting Prevention
Selection
-
1
1
1
1
1
n1-03
Hunting Prevention
Time Constant
ms
10
10
10
10
10
◆
480 V
No.
Name
Unit
Default
-
Bypass
Model
-
B001
B002
B003
B004
B007
B011
B014
B021
B027
B034
B040
o2-04
Drive Model
(KVA)
Selection
Hex.
95
97
99
9A
9B
9D
9E
9F
E2-11
Motor Rated
Power
HP
(kW)
2
(1.5)
4
(3.0)
5
(4.0)
7.5
(5.5)
10
(7.5)
15
(11)
20
(15)
25
(18.5)
b3-04
V/f Gain
during Speed
Search
%
100
100
100
100
100
100
100
100
b3-06
Speed
Estimation
Current Level
1
-
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
b3-08
Speed
Estimation
ACR P Gain
-
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
Summary of Contents for H6B1A002
Page 12: ...12 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Page 74: ...Page Intentionally Blank...
Page 76: ...Page Intentionally Blank...
Page 454: ...5 14 Z Bypass Parameters 454 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Page 590: ...8 6 Storage Guidelines 590 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Page 780: ...11 3 European Standards 780 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...