4.3 Start-up, Test Operation, and Rotation Check
YASKAWA
SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference
127
Note:
If you select [Not now but maybe next time] from the Setup Wizard prompt, the keypad will show the Setup Wizard prompt each
time you energize the bypass.
If you select [No], the keypad will not show the Setup Wizard prompt nor the Initial Setup screen when you energize the bypass.
You can set the date and time or run the Setup Wizard from the Initial Setup screen.
6.
Check for correct motor rotation in Drive Mode and Bypass Mode. Refer to
Test Run and Rotation Check on
for more information about checking and changing motor rotation.
◆
Test Run and Rotation Check
■
Test Run (No Load)
When possible, Yaskawa recommends that you do a test run in Drive Mode and Bypass Mode to check rotation in
both modes before you mechanically connect the motor to the rest of the machine. This is critically important if
running the machine at full speed and/or running the machine in the wrong direction could cause damage or injury.
■
Rotation Check in Drive Mode and Bypass Mode
You must check the rotation in both Drive Mode and Bypass Mode. If the rotation direction is incorrect in Drive
Mode, you must change the output (motor) wiring. If the rotation direction is incorrect in Bypass Mode, you must
change the input power wiring.
Note:
Do the Drive Mode rotation check first. If there are any problems, make sure that you correct them before you do the Bypass Mode rotation
check.
■
Precautions before You Do a Test Run
Before you rotate the motor, check these items:
•
Check for safety issues near the bypass system, motor, and machine.
•
Make sure that all safety, interlock, emergency stop circuits and safety mechanisms are operating correctly.
■
Test Run and Rotation Check - Drive Mode (HAND)
Note:
Yaskawa strongly recommends that you do the items in
Start-up, Test Operation, and Rotation Check on page 125
, including completing the
Setup Wizard before you do this procedure.
1.
Energize the bypass or push
to show the HOME screen.
2.
Push
to make sure that the bypass does not respond to an Auto-Run command.
Summary of Contents for H6B1A002
Page 12: ...12 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Page 74: ...Page Intentionally Blank...
Page 76: ...Page Intentionally Blank...
Page 454: ...5 14 Z Bypass Parameters 454 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Page 590: ...8 6 Storage Guidelines 590 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Page 780: ...11 3 European Standards 780 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...