182
7-7-5. CV Mode
Model
LSG-175H
LSG-350H
LSG-1050H
Operating Range
H Range
5V~800V
L Range
5V~80V
Setting Range
H Range
0V~840.00V
L Range
0V~84.000V
Resolution
H Range
20mV
L Range
2mV
Accuracy of Setting
*1
H, L Range
± (0.2 % of set + 0.2 % of f.s.)
Input current variation
*2
H, L Range
80mV
*1 At the sensing point during remote sensing under the operating range of the
input voltage. It is also applied for the condition of the parallel operation.
*2 With respect to a change in the current of 10 % to 100 % of the rating at an
input voltage of 5 V (during remote sensing).
7-7-6. CP Mode
Model
LSG-175H
LSG-350H
LSG-1050H
Operating Range
H Range
17.5W~175W
35W~350W
105W~1050W
M Range
1.75W~17.5W
3.5W~35W
10.5W~105W
L Range
0.175W~1.75W
0.35W~3.5W
1.05W~10.5W
Setting Range
H Range
0W~183.75W
0W~367.50W
0W~1102.5W
M Range
0W~18.375W
0W~36.750W
0W~110.25W
L Range
0W~1.8375W
0W~3.6750W
0W~11.025W
Resolution
H
レンジ
10mW
10mW
100mW
M
レンジ
1mW
1mW
10mW
L
レンジ
0.1mW
0.1mW
1mW
Accuracy of Setting
*1
±(0.6 % of set + 1.4 % of f.s.
*2
) + Vin
2 *3
/ 3.24MΩ
*1 At the sensing point during remote sensing under the operating range of the
input voltage.
It is not applied for the condition of the parallel operation.
*2 M range applies to the full scale of H range.
*3 Vin = Input terminal voltage of electric load.
Summary of Contents for LSG-1050H
Page 24: ...14 GRA 414 E EIA standard 132 382 5 477 6 GRA 414 J JIS standard 149 382 5 477 6...
Page 185: ...175 7 6 Operating Area 7 6 1 LSG 175H H Range M Range L Range...
Page 186: ...176 7 6 2 LSG 350H H Range M Range L Range...
Page 187: ...177 7 6 3 LSG 1050H H Range M Range L Range...
Page 188: ...178 7 6 4 LSG 2100H H Range M Range L Range...
Page 204: ......