2-2-5. CV, +CV Mode Response Speed
Description
The response speed setting is the response speed for the
negative feedback control of the load current when used
in CV, +CV mode. Response speed settings are only
applicable to CV, +CV mode.
Response speed settings of the +CV mode becomes
same as Response speed settings of the CV mode.
With
the +CV mode, Response speed settings is not
displayed.
The response speed is different from CV mode with the
+CV mode.
A response speed that is too fast could cause the unit to
be unstable.
Reducing the response speed can improve stability.
Operation
1.
Make sure the load is off.
2.
Press
Main
, and make sure the unit is in CV
mode by using the
Mode
[F1] soft-key.
3.
Select the response speed with the
Response
[F4]
soft-key.
Response: Fast, 6, 5, 4, 3, 2, 1, Slow
CV mode:
The response speed settings
Fast, 6, 5, 4 are the same.
+CV mode: The response speed settings
5 and 4 are the same.
The response speed settings
Slow and 1 is the same.
Display
Mode
CV
I Range
H 8.75A
V Range
L 80V
Response
Slow
Configure
0.000
V
0.0000
A
0.00
W
CV B Value
80.000
CV A Value
80.000
LOAD
RS232
A Value
Fine
01/Oct/2017
V
V
Response
setting
Summary of Contents for LSG-1050H
Page 24: ...14 GRA 414 E EIA standard 132 382 5 477 6 GRA 414 J JIS standard 149 382 5 477 6...
Page 185: ...175 7 6 Operating Area 7 6 1 LSG 175H H Range M Range L Range...
Page 186: ...176 7 6 2 LSG 350H H Range M Range L Range...
Page 187: ...177 7 6 3 LSG 1050H H Range M Range L Range...
Page 188: ...178 7 6 4 LSG 2100H H Range M Range L Range...
Page 204: ......