3-6-1. BATT Test function setting parameters
Parameters
BATT No.
Selects one of 12 BATT test setup
memories.
Memo
A user-created note for the currently
selected BATT Test function.
Mode
Select a discharge operation mode. (CC,
CR, CP)
Range
Select I Range (High, Middle, Low)
and V Range (High, Low).
Example:
ILVL(I range Low, V range Low)
Setting
Sets the values corresponding to the
defined discharging mode (CC mode in A,
CR mode in mS and CP mode in W).
Slew Rate
=
Sets the test rising slew rate in mA/us (not
adjustable for CP mode).
Slew Rate
?
Sets the test falling slew rate in mA/us (not
adjustable for CP mode).
Stop Volt
Sets the voltage at which the test should
be interrupted. The value must be lower
than the battery start voltage.
Stop Time
Sets the time after which the test should be
interrupted (max value is 999h: 59m: 59s).
Stop AH
Sets the discharged energy rate at which
the test should be interrupted (Max value is
9999.99Ah).
Datalog timer
Sets the time interval for data capture (1
~
120 seconds). Up to 65,535 data can be
saved when running data logging function.
When logging data reaches to the
maximum amount, it won’t be saved and
be ignored.