2-3-2-3. Von Voltage Latch
Description
When Von Latch is set to OFF, the load will turn off when
the voltage drops below the Von Voltage threshold level.
When Von Latch is set to ON, the load will continue to
sink
current after being “latched”, even if the voltage
drops below the Von Voltage threshold level.
By default Von Latch is set to OFF.
Operation
Press
Main
>
Configure
[F5] >
Other
[F2] in order,
and set the
Von Latch
setting.
Von Latch:
OFF, ON
Von Latch: ON
Voltage
Time
Input voltage
Current
Von
Input current
Time
Load ON
Von Latch: OFF
Voltage
Time
Input voltage
Current
Von
Input current
Time
Load ON
Load OFF