2-5-5. OVP
Description
If the OVP is tripped, the LSG-H Series will turn off the
load. The OVP levels can be set from 0V to 10% higher
than the rated voltage.
Operation
Press
Main
>
Configure
[F5] >
Protection
[F1] in order,
and set the OVP Level.
OVP Level:
OFF, 0~ rated v 5%
Note: To turn OVP off, set the OVP voltage greater than the
current rating v 10%.
Alarm
The OVP indicator and a message will only appear on the
LCD display when the input voltage is below the OVP
level.
Pressing the Enter key will clear the message.
The OVP indicator will remain on the display until the
voltage level falls back above the OVP level.
Note: Please use the input voltage to the LSG-H Series in
800V or less.