186
Model
LSG-175H
LSG-350H
LSG-1050H
Slew Rate Resolution
Resolution
50uA/us
100uA/us
300uA/us
Setting
14mA/us~
140mA/us
28mA/us~
280mA/us
84mA/us~
840mA/us
Resolution
5uA/us
10uA/us
30uA/us
Setting
1.4mA/us~
14mA/us
2.8mA/us~
28mA/us
8.4mA/us~
84mA/us
Resolution
0.5uA/us
1uA/us
3uA/us
Setting
140uA/us~
1.4mA/us
280uA/us~
2.8mA/us
840uA/us~
8.4mA/us
Resolution
50nA/us
0.1uA/us
0.3uA/us
Setting
14uA/us~140uA/us
28uA/us~280uA/us
84uA/us~840uA/us
Resolution
5nA/us
10nA/us
30nA/us
Setting
1.4uA/us~14uA/us
2.8uA/us~28uA/us
8.4uA/us~84uA/us
Resolution
0.5nA/us
1nA/us
3nA/us
Setting
0.14uA/us~
1.4uA/us
0.28uA/us~
2.8uA/us
0.84uA/us~
8.4uA/us
Slew Rate Accuracy of setting *1
±(10% of set + 25us)
*1 Time to reach from 10 % to 90 % when the current is varied
from 2 % to 100 % (20 % to 100 % in M range) of the rated
current.
Current Setting Range
H Range
0A~9.1875A
0A~18.375A
0A~55.125A
M Range
0A~0.91875A
0A~1.8375A
0A~5.5125A
L Range
0mA~91.875mA
0mA~183.75mA
0A~0.55125A
Current Resolution
H Range
0.3mA
0.6mA
2mA
M Range
0.03mA
0.06mA
0.2mA
L Range
0.0003mA
0.006mA
0.02mA
Current Accuracy
±0.4% of f.s.
Summary of Contents for LSG-1050H
Page 24: ...14 GRA 414 E EIA standard 132 382 5 477 6 GRA 414 J JIS standard 149 382 5 477 6...
Page 185: ...175 7 6 Operating Area 7 6 1 LSG 175H H Range M Range L Range...
Page 186: ...176 7 6 2 LSG 350H H Range M Range L Range...
Page 187: ...177 7 6 3 LSG 1050H H Range M Range L Range...
Page 188: ...178 7 6 4 LSG 2100H H Range M Range L Range...
Page 204: ......