4-1-6. External Resistance Control
– Operation
Description
External resistance control can be used to control the current,
voltage, resistance and power for CC, CR, CV and CP modes.
Configuration for each the operating mode is the same.
CC Mode
Proportional Control:
Input current = rated current × (external resistance/10).
Inverse Control:
Input current = rated current ×
(1 - external resistance/10).
Input
Current
0
Ω
10k
Ω
External
Resistance
Rated
Current
offset adjusment
full scale adjusment
0A
after adjusment
before adjusment
Proportional control
Inverse control
CR Mode
Proportional Control:
Input conductance = rated conductance ×
(external resistance/10).
Inverse Control:
Input conductance = rated conductance ×
(1 - external resistance/10).
Rated
Conductance
Input
Conductance
0
Ω
External
Resistance
offset adjusment
full scale adjusment
0S
before adjusment
10k
Ω
after adjusment
Inverse control
Proportional control